Model 105 SP Dryer Specifications

  • 105 cubic feet steam-heated dryer
  • Two-door pass-through
  • One-way tilt
  • PLC controls

Recommended Capacity

200-285 lbs. dry weight.

Basket

The basket shall have a volume of 105 cu. ft. and shall be constructed of 10 gauge perforated metal with 3 main and 3 secondary lifting ribs, supported by four 10” polyurethane rollers equipped with timken roller bearings and guided at each end by a total of four 5” polyurethane rollers equipped with timken roller bearings. All rollers shall be located outside of the sealed heating chamber.

Basket Doors

The basket doors shall be a minimum of 42” in diameter and shall seal to and rotate with the basket to prevent the possibility of damage to products being dried. They shall be operated by an air over oil mechanism for smooth opening and closing. There shall be two basket doors to provide for loading at one end and unloading at the opposite end of the basket.

Basket Drive

The basket shall be driven by v-belts around the circumference of the basket. There shall be a self-adjusting, constantly variable tension device to keep the belts properly tensioned. The belts shall be located outside of the sealed heating chamber.

Optional Basket Cleaning

If specified, there shall be a device to automatically keep basket perforations open and clear of plastic residue to insure efficiency of air movement.

Machine Tilt

The main housing shall tilt a minimum of 18º to facilitate fast and easy loading and unloading of the machine. The tilt mechanism shall consist of two 5” i.d. double-cushioned air cylinders.

Heat and Cool Down System

Heat shall be supplied by two steam/air heat exchanger coils utilizing cupro-nickel tubing and silver solder with an automatic cold air bypass. All necessary traps and valves shall be included (optional).

Heat Control

Heating and cool-down shall be PLC controlled.

Exhaust System

The exhaust blower shall be single inlet, dynamically balanced and belt driven from a 10 hp motor to afford a minimum air flow of 6000 cfm. There shall be a device to automatically clean accumulated lint from the rotor at the beginning of each cycle.

Optional Outside Air Makeup

If specified, there shall be a means of providing makeup air directly to the burner and combustion chamber from outside the plant to prevent negative air pressure within the plant. The inlet duct shall have a minimum diameter of 26”.

Electric Motors

Exhaust blower 10 hp
Basket drive 3 hp

SERVICES

Electricity

Varies with voltage characteristics
60 fla at 230v

Air

1/2” npt connection
80 psi minimum

Water

3/4” npt connection
80 psi minimum

Steam

1-1/2” npt inlet connection
1” npt return connection
100 psi minimum pressure
125 psi optimum pressure
20 bhp average hourly consumption

Exhaust Duct

Minimum 18” diameter or 260 sq. in. Maximum 1.0” wc backpressure

PLC controls shall provide:

A. Sealed, color touch-control panel to program and control machine functions including start & stop, reverse/non-reverse selection and recirculation time.

B. Full color readout of inlet & outlet temperatures, time, program number, faults, dryer cycle, excess exhaust back-pressure and other pertinent information.

C. Ninety six (96) user programmable drying formulas with multi-level password protection to prevent operators from over-riding management decisions.

D. Ability to automatically dry or dry by time, cool-down by time or to programmed temperature, dry by inlet temperature or outlet temperature.

E. Optional ability to transfer programs to other Consolidated dryers with PLC controls.

F. Control heat and cool down.

G. Lint trap controls for optional Consolidated lint collector.

Optional Stainless Steel Dry Lint Collector

If specified, a stainless steel lint collector shall be built onto and integrated with dryer including integral air receiver for end-of-cycle lint blowdown. There shall be a separate lint collector automatic fire safety suppression system with alarm, but no separate utility connections to lint collector shall be required, and transition to lint collector shall be factory installed. The only connection required to lint collector shall be that of a single 18” diameter exhaust duct to the atmosphere. Lint shall automatically be removed to a large lint bag at theend of each cycle.

Interlocks, safety devices & other features shall consist of:

  • Automatic fire safety suppression system with alarm
  • Exhaust blower rotation sensor
  • Blower burner rotation sensor
  • Basket rotation sensor
  • Tilt interlock safety switches
  • Door safety switches
  • Guards on moving parts
  • Tilt and door warning bell
  • Electrical interlock to prevent door and tilt mis-operation
  • Door opens on power failure
  • Circuit breaker w/mechanical interlock to prevent opening of electrical panel with power on
  • Thermal overload protection devices for all motors
  • Both hands required to close doors
  • Manual fire suppression system switch with guard to prevent accidental activation
  • Bell and light to indicate end of cycle
  • Momentary basket jogging switch

Shipping weight

6500 pounds.